Input |
---|
Number of Channels | 2 analog channels 1 syncronization channel | Input types | ICP® or charge accelerometer (2 ch.) Linear voltage (2 ch.) Phase reference tacho (TTL) | Sensor types | accelerometer, current clamps, microphone, tacho probe | Integration | analog (1 stage), digital (1 or 1 stages) | Frequency range | 0.1 – 25600 Hz | Frequency range (+0.5dB) | 0.5 – 25600 Hz | Linear input signal range | +\- 3 V | Phase difference between channels | in 2..300 Hz 1 degree or less in 301..1000Hz 5 degres or less | Between channel interference | – 100 dB or better | Gain | AUTO, 0-54 dB in 6 dB steps | | Vibration parameters |
---|
Measured magnitudes | displacement, velocity, acceleration, peak-factor | Detector | RMS, true peak, peak-peak | Frequency bands for vibration | ISO standard: | 2..1000, 10..1000, 10..2000 Hz |
| additional: | 2..200, 3..300, 5..500, 10..5000, 500..2500, 625..1250, 1200..2500, 2500..5000, 5000..10000, 10000..25000, 17000..25000 Hz |
| Vibration range | acceleration (on 160 Hz) from 0.05 up to 1000 m/s2 velocity (on 80 Hz) from 0.1 up to 100 mm/s displacement (on 40 Hz) from 1 up to 1000um | | FFT spectra |
---|
Frequency span | 25, 50, 100, 200, 400, 800, 1600, 3200, 6400, 12800, 25600 Hz | Frequency resolution | 400, 800, 1600 lines | Dynamic range | 90 dB or better | Linear averages | 1-256 | Weighting function | Hanning | Scale Type | Linear or logarythmic | Envelope detector Band pass filters with center frequencies | 1/3 octave: | 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000, 5000, 6400, 8000, 10000, 12800, 16000, 20000 Hz |
| 1/1 octave: | 50, 100, 200, 400, 800, 1600, 3200, 6400, 8000, 12800, 16000 Hz |
| | Time waveform |
---|
Sampling frequencies | 64, 128, 256, 512, 1024, 2048, 4096, 8192, 16384, 32768, 65536 Hz | Number of samples | 200, 400, 1000, 2000, 4000 | Envelope detector Band pass filters with center frequencies | 1/3 octave: | 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000, 5000, 6400, 8000, 10000, 12800, 16000, 20000 Hz |
| 1/1 octave: | 50, 100, 200, 400, 800, 1600, 3200, 6400, 8000, 12800, 16000 Hz |
| | Amplitude and Phase measurements |
---|
Frequency range | 0.5-1700 Hz (30-102000 RPM) | RPM error | + 1% | Phase measurement error | + 5 degrees | Amplitude error | + 1 dB | Automatic control | tacho signal parameters reliability of measurements | Amplitude measurement units | G, m/s2, mm/s, mm, in/s2, in/s, mil RMS, Peak, or Peak to Peak | Internal power supply for phase reference tacho | 5 V DC, 15 mA | | Overall Measurements | Bands | 2-1000 Hz, 10-1,000 Hz, 10-20,000 Hz, 10-5,000 Hz, 5-10 kHz,10-25 kHz, 2-200 Hz, 5-500 Hz | Detector Type | RMS, Peak, Peak to Peak, Peak Factor | Scale Type | Linear or log | Units | g, m/s^2, mm/s, mm, V, in/s, mils | | RPM-amplitude-frequency measurements for run-up/coast-down | Rotation speed range | 0.5-1700 Hz (30-102000 RPM) | Frequency range | from 0.5 Hz up to 10xRPM | RPM resolution | up to 200 lines on two harmonics | Measurements are done on | 1-6th harmonics of rotation speed | | General |
---|
Operation Temperature | -20 / +50C (5/ 120F) | Weight | 0.9 kg | Dimensions | 109(W) x 208(L) x 35(H) mm | Battery type | Nickel Metal Hydride | Operation time from batteries | 10 hours with reserve battery | Battery full charge time | 2 hours | Power management | Adjustable auto shut down Adjustable auto backlight switch off | Data storage capacity | 800 spectra | Interfaces | RS-232 |
| |